  • POST a QUESTION or COMMENT about where to find Heil furnace or boiler installation and service or maintenance manuals and guides

Heil Manuals, parts lists, wiring diagrams for HVAC equipment:

Free downloadable Heil manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for Heil who can provide that information for nearly all major brands of HVAC equipment.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Editor/Publisher - See WHO ARE WE?

Heil Heaters, Furnaces, Air Conditioners, Furnaces, Boilers: parts, manuals, help

Free Heil-brand Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists

Above: the OLV QuietComfort®87 ow Boy Oil Furnace, described at the Tempstar website, a member of the ICP or International Comfort Products company, whose furnace warranty names the Carrier Corporation, and whose furnace is also sold under the Heil Heating & Cooling Products brand (Screenshot just below, 2021/05/17 taken at https://www.heil-hvac.com/en/us/products/oil-furnaces/87-low-boy-oil-furnace/)

  • Contact: HEIL is a Carrier Corporation company, in turn listed under ICP or International Comfort Products as you'll read below.

    USA: Heil Heating & Cooling Products: International Comfort Products650 Heil Quaker AvenueP.O. Box 128Lewisburg, Tennessee 37091 USA, Tel: (931) 270­4100

    Canada:International Comfort ProductsDivision of UTC Canada Corporation6060 Burnside Court, Unit 1Mississauga, Ontario L5T 2T5(905) 795­8113

    Website: (May 2021) https://www.heil-hvac.com/

    Dealer Website: http://www.goheil.com/

    Really? Good luck trying to find company contact information on the company's website. The company wants you to contact your local Heil dealer. The Heil "Learning Center" is available to registered dealers but is not open to the public. (May 2021)

Heil-Quaker was a Whirlpool brand, bought by Inter-City Gas, in Toronto. ICG re-branded Whirlpool products using the Tempstar brand, and the Heil-Quaker product line is currently owned by ICP International Comfort Products who in-turn were bought by United Technologies in 1999.

  • Also see ICP INTERNATIONAL COMFORT PRODUCTS

Heil HVAC Age Decoder

Heil HVAC equipment manufacturing date is usually encoded in the serial number

YYWW567890

or in the serial number format

XYYWW56790

(ignore the first alphabetic character, pick up the first four numeric digits, and decode them as YYWW as we illustrate here.

Use the first four numeric digits that form YYWW where YY is year of manufacture and WW is week of manufacture in that year.

The remaining numeric digits, usually 5, form a unique serial numer or manufacturing sequence number of the equipment.

This same manufacturing date encoding appears in most HVAC equipment distributed under the ICP brands of:

Arcoaire, Comfortmaker, Heil, ICP, International Comfort Products, Inter-City Products, Keeprite, Tempstar, and UTC, United Technologies Inc.,

Heil HVAC Service Manuals, Parts Lists, Warranties

  • - also see
  • HEIL OIL FURNACE LOW BOY OLR OLV INSTALLATION MANUAL [PDF] (2019) Current Models OLR098A12A and OLV098A12A
  • HEIL LOW BOY OIL FIRED FURNACE MANUAL OLR- OLV- Series [PDF] (2010) (obsolete) Models OLR098A12A and OLV098A12A
  • [PDF] (obsolete)
  • HEIL RGX036-060 R-410A Package Rooftop Gas/Electric Cooling INSTALLATION MANUAL [PDF] (obsolete)
  • Heil HEAT PUMP HIGH PRESSURE SWITCH REMOVAL UPDATE - UL 1990 [PDF]

    Excerpt:

    Changes to UL 1995 HVAC requirements and improved, built-in compressor protections have allowed us toremove the high-pressure switch from R-Series and N-Series heat pumps. The updated heat pump modelsare being produced now and will be phased in as inventory of current models are sold.

    What is UL 1995, and what changed?UL 1995 is the standard of safety for heating and coolingequipment and is adhered to by HVAC manufacturers in theUnited States and Canada.

    The revised requirements no longerspecify the need for a high-pressure switch in R-410A heatpump applications.

    This is due in part to internal protectionsnow built into heat pump compressors. However, removal of thehigh-pressure switch is not a requirement.

  • HEIL SPLIT SYSTEM HEAT PUMP MODELS / CATALOG [PDF] (2020) Heil - Carrier Corp.
  • Heil SPLIT SYSTEM HEAT PUMP OWNER'S INFORMATION GUIDE [PDF] (2021) this guide will apply to Heat Pumps from Carrier & Carrier brand subsidiaries such as Heil.

    Excerpts:

    Operation under Extreme Conditions

    Your heat pump will run as long as necessary to maintain the indoortemperature selected on your Ion™ Control or thermostat. On extremelyhot days, your heat pump will run for longer periods at a time than onmoderate days.

    Your system will also run for longer periods of timeunder the following conditions:

    • Frequent opening of exterior doors• Operating laundry appliances
    • Taking hot showers
    • More than the usual number of people present in the home
    • More than the normal number of electric lights in use
    • Drapes or blinds are open on the sunny side of the home

    Watch out: Do Not Operate Above 66°F (19°C) in Heating Mode

    Your outdoor unit is not designed to operate in heating mode whenoutdoor temperatures are above 66°F (19°C).

    You can safely operate thesystem above 66°F (19°C) on emergency or auxiliary heat.

  • (2-11) [PDF]
  • HEIL GEOTHERMAL HEAT PUMP START-UP CHECKLIST [PDF] (2015)
  • [PDF] (2012) DFS4, DFC4, DFF4 R410A AC/HP Duct Free Split System Parts, Technical Support Manual (7-12)
  • [PDF] (2012) T4H3, C4H3,H4H3 13 SEER R-410A HP Technical Support & Parts Lists (6-12)
  • [PDF] (2014) DL(F,C)4(A/H)09-24(J/k)A1 16 SEER, UP TO 8.6 HSPF, R-410A Ductless High Wall Split System AC/HP Service Manual (2-14)
  • HEIL SPLIT SYSTEM AIR CONDITIONER SPECIFICATIONS 1 1/2 Tons through 5 Tons [PDF] (2008) Outoor models CA5518*KD / CA5524*KD, Indoor Models EP, EPD, EEA, EX, FC-series, 17,500 BTUH to 24,200 BTUH
  • Heil Technical Literature Search: http://goheil.com/go/index.asp?t=86&s=477 (May 2021) you'll need the 3-5 character product identification characters to perform a search
  • HEIL HEAT PUMP WARRANTY [PDF]
  • HEIL RESIDENTIAL WARRANTIES [PDF]
  • Heil HVAC Equipment Warranties: are available through the company's websites listed above.

    A typical warranty such as the "Commercial Rooftops and Commercial Split System Products warranty" listed below display ICPor International Comfort Products as the warranting company at the document top.

    Also see

  • HEIL WARRANTY: Commercial Rooftops and Commercial Split System Products [PDF] (2015)

    Excerpt:
    FOR WARRANTY SERVICE OR REPAIR:
    Contact the installer or an International Comfort Products dealer. You may be able to find the installer's name on the equipment or in your Owner's Packet. You can also find an International Comfort Products dealer online at www.icpusa.com.

    For help, contact: International Comfort Products, Consumer Relations, P.O. Box 4808, Syracuse, New York, 13221, Phone 1-877-591-8908.

    Product registration: You can register your product at https://productregistration.icpusa.com

  • Also see HEAT RECOVERY VENTILATOR RECALL On Heil and other HRVs

ADVERTIsem*nT


Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see

On 2021-08-09 by inspectapedia.com.moderator (mod) - Heil furnace trips breaker

@Anonymous,

That sounds to me like a control board or relay failure - since we know the fan itself works as it runs in Heat mode - but not in A/C mode.

On 2021-08-09 by Anonymous

@inspectapedia.com.moderator, the breaker doesn't trip again once it's flipped. Just the one time it tripped. The fan will come on if I turn system heat on.

On 2021-08-09 by inspectapedia.com.moderator (mod) - Heil furnace fan won't turn on in AC mode

@Anonymous,

The "fan won't start" diagnostics above on this page are a good set of things to check first; do take a look.

A tripped breaker may mean that there is a short circuit or failing fan motor - flip the breaker to OFF then back ON.

If it trips again leave it off and call for repair.

On 2021-08-09 by Anonymous

I have a heil sp80 and the fan inside the house won't kick on with AC on. The unit outside fan does kick on.

I noticed the line also frosted so i think the compressor kicked on. The blower inside the house does kick on when I turn on system heat. There was a breaker kicked when I discovered ac wasn't working. Any help greatly appreciated!

On 2021-03-22 - by (mod) -

Note to other readers

You can find free HVAC equipment manual downloads as PDF files at
- home - Master Index to All Brand Names & A - E HVAC manuals, wiring diagrams, installation and repair guides including for
CONSOLIDATED INDUSTRIES FURNACES information and manuals

On 2021-03-22 - by (mod) -

@joedave, That sounds reasonable to me. You know the fan works because you can run it on manual. Take a look at the fan limit switch on your furnace. It's probably a standard Honeywell unit like those shown in the series.

On 2021-03-22 by joedave - the limit control switch needs to be replaced. fan runs on manual, only

pretty much i think the problem is the limit control switch needs to be replaced. fan runs on manual, only. although, i did hear the fan come on by itself a week or so back. overnight, i have the themostat at 62, and fan on auto. anyway, thank you for mentioning that the honeywell module has a metal cover, which must be missing on this particular furnace.

it's a HEIL NULK075AG02 serial H611 33891. just thought, maybe the honeywell number i need is on the missing cover. anyway. the furnace may have started out LP, but is running on NG, now.

so, which honeywell part do i need? also, when i bought the inducer fan assembly last year, they gave me what i thought was a flame sensor, that i took back because i couldn't see how to install it. current one has fittings pointing up, and their replacement had horizontal which would have required bending something. force-fitting is usually an indication of a wrong choice, i find. thanks for your help

On 2019-06-29 by Mod: Heil HVAC Error Code Lists

Bob see the manuals and error code lists given at

On 2019-06-29 by Bob

Heil Heat Pump/AC Model H4H548GKA100 has shut down. Giving error code 40?

On 2017-11-10 by Dennis - thermocouple for Heil-Quaker Gas furnace

@Dennis

See THERMOCOUPLE REPAIR / REPLACEMENT - you'll find that thermocouples are a standard, generic part, easy to locate and replace.

On 2017-11-10 by Dennis - need thermocouple for Heil-Quaker furnace

How do I find out what the proper part is? It's a 30 year old Heil-Quaker furnace and searches don't come up with compatible parts. I don't know if there is a standard for forced air gas furnaces.

On 2017-03-17 by (mod) -

Stan in the long list of FAN LIMIT SWITCH articles at the end of this page be sure to check

FAN LIMIT CONTROL SETTINGS

as that gives the right fan ON OFF and LIMIT settings as well as warning you about how easy it is to bend and damage the control - leaving it out of calibration and also unsafe.

The blower shouldn't be turning on until the ON number has been reached.

On 2017-03-17 by stan

i got a heil furance with a limit control i set the dial settings at 100 second one at 140 the problem is when the flame starts before the fan on hits the the 140 setting the blower is all ready running at about 140 the flame turns off blower turns off at about 100

On 2016-12-28 by (mod) - contact Heil Environmental Corporate Office

Rob: provided the thermal sensor is of proper dimension that'll probably work. I would give Heil a call to confirm what replacements they agree are safe.

Heil Environmental Corporate Office
2030 Hamilton Place Boulevard Suite 200
Chattanooga, TN 37421 USA
Phone: 866.367.4345
e-Mail: corp@doveresg.com

On 2016-12-28 by Rob

I have a HEIL furnace that uses an R02I005 2 speed fan-limit switch, comparable to Honeywell L6064 fan-limit switch.

Both have been discontinued, can I replace it with a single speed fan-limit switch such as the Honeywell L4064B2236?

On 2016-11-20 by Luke H

My Heil Lincoln series fuel oil furnace recently started short cycling. The burner would kick in run for less than a minute, then kick back off.

The blower wouldn't run until 20 seconds after the burner shut off. I eventually traced the problem back to the thermostat, a Honeywell T87F. The anticipator must have developed a short and wouldn't respond to any adjustments I made. Replaced it with a programmable Lux t-stat with an adjustable deadband (swing). Your website made troubleshooting this problem go very fast. Thanks!


...

Continue reading at ICP INTERNATIONAL COMFORT PRODUCTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

  • AGE of WATER HEATERS - data tag decoding, contact information for water heater manufacturers, water heater manuals
  • AGE of HEATERS, BOILERS, FURNACES
  • - home
  • BOILERS, HEATING - home
  • DATA TAGS on AIR CONDITIONERS for help decoding the equipment age and other specification
  • FURNACES, HEATING - home
  • in Spanish
  • HEAT RECOVERY VENTILATOR RECALL - includes some Heil brand units.
  • - home - Master Index to All Brand Names & HVAC manuals, wiring diagrams, installation and repair guides

Suggested citation for this web page

at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES:

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Or see

INDEX to RELATED ARTICLES: ARTICLE INDEX to HEATING SYSTEMS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.

  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.

  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.

    Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The HOME REFERENCE BOOK- the Encyclopedia of Homes and to use illustrations from The ILLUSTRATED HOME .

    Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.


ADVERTIsem*nT

InspectApedia Diagnose & Fix What's Wrong at Your Building (2024)

References

Top Articles
Latest Posts
Article information

Author: Delena Feil

Last Updated:

Views: 5831

Rating: 4.4 / 5 (45 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Delena Feil

Birthday: 1998-08-29

Address: 747 Lubowitz Run, Sidmouth, HI 90646-5543

Phone: +99513241752844

Job: Design Supervisor

Hobby: Digital arts, Lacemaking, Air sports, Running, Scouting, Shooting, Puzzles

Introduction: My name is Delena Feil, I am a clean, splendid, calm, fancy, jolly, bright, faithful person who loves writing and wants to share my knowledge and understanding with you.